Routine
September 10, 2026
- Risk factorsItems found out of compliance among the 29 on the state’s inspection form most closely tied to foodborne illness, such as holding temperatures and handwashing. One corrected while the inspector was there still counts.
- 1
- Retail practicesItems 30 and up on the form found out of compliance: cleanliness, equipment, labeling, allergen notices and the like. One corrected while the inspector was there still counts.
- 3
- RepeatViolations the department marks as repeated from an earlier inspection.
- 0
Risk factors 1
- 28
Toxic substances properly identified, stored and used7-204.11
Observed bucket of sanitizer at 800ppm which is above the manufacturer approved ppm to sanitize food contact surfaces. 3 compartment dispenser is premeasured for a full 3 compartment sink mixture and would not be the right concentration for the small sanitizer buckets. EHS recommends to fill 3 compartment sink with mixture, test with test kit, and fill buckets from 3 compartment sink. PIC remixed to correct.
Retail practices 3
- 47
Food and non-food contact surfaces cleanable, properly designed, constructed, and used4-101.19
Observed hand sink by the prep cooler and the 3 compartment sink to need resealed to the wall. Nonfood-contact surfaces of equipment that is exposed to splash, spillage, or other food soiling is not constructed of corrosion-resistant, nonabsorbent, and smooth material. Correct by next inspection.
- 51
Plumbing installed; proper backflow devices5-202.13
Observed hose connected and in the basin of the mop sink. There is no backflow preventor on the sink to prevent backsiphonage. Water fixtures that do not have backflow prevention devices installed shall provide an air gap between the water supply and the flood rim of the fixture to prevent backsiphonage. Provide an air gap of at least 1 inch or a backflow device. PIC removed hose to correct on site. EHS recommends to install a backflow device on the spigot of the sink so that the hose may remain attached.
- 51
Plumbing installed; proper backflow devices5-205.15(B)
Observed leak at the 3 compartment sink. Plumbing systems shall be maintained in good repair to prevent escalating issues, i.e., leaks addressed with urgency.


The inspector’s comments
Core Violations noted on this inspection shall be corrected within 90 calendar days, or by no later than the next routine inspection if no health hazard exists or will result from allowing the extended schedule for compliance. This comment shall serve as a written extended schedule of compliance as agreed upon by the permit/license holder and the regulatory authority.